Millimar |
Module for inductive probes
Millimar N 1704 T
Art. no. 5331141
Module for inductive probes Millimar N 1704 T
- Flexibly configurable RS485 bus modules
- Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
- Synchronous data retrieval from multiple connected measuring probes
- Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
- Connects all compatible probe types using one module
- Flexible and modular product combinations to tackle customer-specific measuring tasks
- Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)
instruction manual
- Flexibly configurable RS485 bus modules
- Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
- Synchronous data retrieval from multiple connected measuring probes
- Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
- Connects all compatible measuring probe types using one module
- Flexible and modular product combinations to tackle customer-specific measuring tasks
- Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)
Millimar N 1704 T | Art. no. 5331141 | |
---|---|
Product type | N 1704 T |
Resolution µm | 0,1 |
Error limit | 0,3 % (min. 0,2 μm) |
Energy supply | + 5V from N 1700 Bus |
Probe inputs | 4 |
Working temperature MAX | 35 °C |
Product weight | 0.394 kg |
Current consumption | 150 mA |
Compatibility | Tesa |
Working temperature MIN | 10 °C |
Data transmission rate | 4189 Hz |
Operating temperature up to | 40 °C |
Data interface | RS-485 |
Operating temperature from | 0 °C |
Temperature coefficient | 0.02 µm/°C |
Measuring range, inductive probe | ± 5000 , ± 2000 , ± 1000 , ± 500 |
IP protection category | IP 42 |
Configuration | Millimar Cockpit Software |
Variety of applications for our products
Smart and flexible combination of measuring modules and software for solving customer-specific measuring tasks.
Label | Art. no. | Product type | Measuring range from | Measuring force (N) | Compatibility | Lifter / retraction | Measuring range up to | Increase in measuring force | Cable length | Linearity deviation within +/- 0,5 mm | Linearity deviation within +/- 1,0 mm | Operating temperature up to | Distance of upper stop MIN | Operating temperature from | Distance of upper stop MAX | Storage temperature MAX | Distance of lower stop MIN | Repeatability fw (µm) | Storage temperature MIN | Distance of lower stop MAX | Temperature coefficient | Measuring value hysteresis fu (µm) | IP protection category | Sensitivity deviation | Reference temperature | Working temperature MAX | Working temperature MIN | Linearity deviation within +/- 2,0 mm | Linearity deviation within +/- 5,0 mm | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inductive probe P1300 TA |
4400190 | P1300 TA | -2 mm | 0,75 N +/- 0,15 N | Tesa | Vacuum lifter (standard option) | 2 mm | 0,3 N/mm | 2.5 m | 1 µm | 3 µm | 40 °C | 2.2 mm | 10 °C | 4.4 mm | 80 °C | -2.2 mm | 0.1 µm | -10 °C | 0 mm | 0.15 µm/°C | 0.5 µm | IP 64 | 0.3 % | ||||||
Inductive probe P1300 TA without cable |
4400192 | P1300 TA without cable | -2 mm | 0,75 N +/- 0,15 N | Tesa | Vacuum lifter (standard option) | 2 mm | 0,3 N/mm | 1 µm | 3 µm | 40 °C | 2.2 mm | 10 °C | 4.4 mm | 80 °C | -2.2 mm | 0.1 µm | -10 °C | 0 mm | 0.15 µm/°C | 0.5 µm | IP 64 | 0.3 % | |||||||
Inductive probe P1300 TB |
4400191 | P1300 TB | -2 mm | Depending upon air pressure | Tesa | Compressed air retraction (max. 1 bar) | 2 mm | 2.5 m | 1 µm | 3 µm | 40 °C | 2.2 mm | 10 °C | 4.4 mm | 80 °C | -2.2 mm | 0.1 µm | -10 °C | 0 mm | 0.15 µm/°C | 0.5 µm | IP 64 | 0.3 % | |||||||
Inductive probe P1300 TB without cable |
4400193 | P1300 TB without cable | -2 mm | Depending upon air pressure | Tesa | Compressed air retraction (max. 1 bar) | 2 mm | 1 µm | 3 µm | 40 °C | 2.2 mm | 10 °C | 4.4 mm | 80 °C | -2.2 mm | 0.1 µm | -10 °C | 0 mm | 0.15 µm/°C | 0.5 µm | IP 64 | 0.3 % | ||||||||
Inductive probe P2004 T |
5323011 | P2004 T | -2 mm | 0,75 N +/- 0,15 N | Tesa | Standard model | 2 mm | 0,2 N/mm | 2.5 m | 0.4 µm | 1.5 µm | 40 °C | 2.2 mm | 10 °C | 4.4 mm | 80 °C | -2.2 mm | 0.1 µm | -10 °C | 0 mm | 0.15 µm/°C | 0.5 µm | IP 64 | 0.3 % | 20 °C | 40 °C | 10 °C | 3 µm | ||
Inductive probe P2004 TA |
5323021 | P2004 TA | -2 mm | 0,75 N +/- 0,15 N | Tesa | Vacuum lifter | 2 mm | 0,2 N/mm | 2.5 m | 0.4 µm | 1.5 µm | 40 °C | 2.2 mm | 10 °C | 4.4 mm | 80 °C | -2.2 mm | 0.1 µm | -10 °C | 0 mm | 0.15 µm/°C | 0.5 µm | IP 64 | 0.3 % | 20 °C | 40 °C | 10 °C | 3 µm | ||
Inductive probe P2004 TB |
5323031 | P2004 TB | -2 mm | Depending upon air pressure | Tesa | Compressed air retraction (max. 1 bar) | 2 mm | 2.5 m | 0.4 µm | 1.5 µm | 40 °C | 2.2 mm | 10 °C | 4.4 mm | 80 °C | -2.2 mm | 0.1 µm | -10 °C | 0 mm | 0.15 µm/°C | 0.5 µm | IP 64 | 0.3 % | 20 °C | 40 °C | 10 °C | 3 µm | |||
Inductive probe P2010 TA |
5324021 | P2010 TA | -5 mm | 0,75 N +/- 0,15 N | Tesa | Vacuum lifter | 5 mm | 0,1 N/mm | 2.5 m | 40 °C | 10 °C | 5.3 mm | 80 °C | 0.2 µm | -10 °C | -5.3 mm | 0.15 µm/°C | 1 µm | IP 64 | 0.3 % | 20 °C | 40 °C | 10 °C | 4 µm | 20 µm | |||||
Inductive probe P2010 TB |
5324031 | P2010 TB | -5 mm | Depending upon air pressure | Tesa | Compressed air retraction (max. 1 bar) | 5 mm | 2.5 m | 40 °C | 10 °C | 5.3 mm | 80 °C | 0.2 µm | -10 °C | -5.3 mm | 0.15 µm/°C | 1 µm | IP 64 | 0.3 % | 20 °C | 40 °C | 10 °C | 4 µm | 20 µm | ||||||
Inductive probe P2104 TA |
5324071 | P2104 TA | -2 mm | 0,75 N +/- 0,15 N | Tesa | Vacuum lifter | 2 mm | 0,1 N/mm | 2.5 m | 0.5 µm | 2 µm | 40 °C | 8.4 mm | 10 °C | 10.4 mm | 80 °C | -2.2 mm | 0.2 µm | -10 °C | 0 mm | 0.15 µm/°C | 1 µm | IP 64 | 0.3 % | 20 °C | 40 °C | 10 °C | 4 µm | ||
Inductive probe P2104 TB |
5324081 | P2104 TB | -2 mm | Depending upon air pressure | Tesa | Compressed air retraction (max. 1 bar) | 2 mm | 2.5 m | 0.5 µm | 2 µm | 40 °C | 8.4 mm | 10 °C | 10.4 mm | 80 °C | -2.2 mm | 0.2 µm | -10 °C | 0 mm | 0.15 µm/°C | 1 µm | IP 64 | 0.3 % | 20 °C | 40 °C | 10 °C | 4 µm |