Precimar |
Length measuring bench
Precimar SM 60
Art. no. 5357360
Length measuring bench for external measurements with 60 mm application range
The Precimar SM 60 is an easy-to-use measuring instrument for fast, precise external measurements on workpieces.
- Simple setup of the device
- Can be used close to production due to robust design
- Quick adaptation to new workpieces
- Freely selectable measuring equipment (e.g. digital dial gage, probe etc.)
- Built-in coupling protects the measuring equipment used
- Measuring surfaces with hardened contact surface
- Use of a wide variety of measuring attachments
- Operation for left- and right-handed users
- Sliding measuring sleeve
Precimar SM 60 | Art. no. 5357360 | |
---|---|
Application range mm | 0 - 60 |
Device dimensions | 285 x 80 x 100 (ohne Bedienelemente) 290 x 140 x 120 (mit Bedienelemente) |
Direct measuring range [mm] | 25 |
Measuring forces [N] | 1 N + measuring force of measuring system |
Mass [kg] | 9 |
Label | Art. no. | Measuring span in mm | Product type | Measuring span (inches) | Resolution | Graduation value mm | Standard | Graduation value inches | IP protection category | Battery type | Range of analog display mm | Range of analog display inches | Error limit (mm) | Repeatability mm | Measuring force (N) | Height of digits | Display | Range of digital display µm | Range of digital display inch | Range of analog display µm | Resolution µm | Graduation mm | Graduation value inches | Probe inputs | Compatibility | Measuring combination | Features | Test steps | Dynamic functions | Configuration | Refresh rate | Data transmission rate | Error limit, digital display | Error limit, analog display | Data interface | Hardware interfaces | Energy supply | Working temperature MIN | Working temperature MAX | Operating temperature Min | Operating temperature Max | Product weight | Measuring range from | Measuring range up to | Distance of lower stop MIN | Distance of lower stop MAX | Distance of upper stop MIN | Distance of upper stop MAX | Lifter / retraction | Increase in measuring force | Sensitivity deviation | Repeatability fw (µm) | Measuring value hysteresis fu (µm) | Linearity deviation within +/- 0,5 mm | Linearity deviation within +/- 1,0 mm | Linearity deviation within +/- 2,0 mm | Cable length | Working temperature | Storage temperature MIN | Storage temperature MAX | Temperature coefficient | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Digital dial indicator 1087 R |
4337661 | 25 mm | 1087 R | 1" | 0.0005 mm , 0.001 mm , 0.002 mm , 0.005 mm , 0.01 mm | 0,0005 , 0,001 , 0,002 , 0,005 , 0,01 | Factory standard | .000002'' , .00005" , .0001'' , .0002'' , .0005" | IP 42 | CR 2450N (3V Lithium) | ± 0,01 , ± 0,02 , ± 0,04 , ± 0,1 , ± 0,2 | ± .0004" , ± .001'' , ± .002" , ± .004" , ± .01'' | 0.004 mm | 0.001 mm | 0.65 - 1.15 | 8.5 mm | ||||||||||||||||||||||||||||||||||||||||||||||
Digital dial indicator 1087 Ri |
4337665 | 25 mm | 1087 Ri | 1" | 0.0005 mm , 0.001 mm , 0.002 mm , 0.005 mm , 0.01 mm | 0,0005 , 0,001 , 0,002 , 0,005 , 0,01 | Factory standard | .000002'' , .00005" , .0001'' , .0002'' , .0005" | IP 42 | CR 2450N (3V Lithium) | ± 0,01 , ± 0,02 , ± 0,04 , ± 0,1 , ± 0,2 | ± .0004" , ± .001'' , ± .002" , ± .004" , ± .01'' | 0.004 mm | 0.001 mm | 0.65 - 0.9 | 8.5 mm | ||||||||||||||||||||||||||||||||||||||||||||||
Digital dial indicator 1086 R |
4337621 | 25 mm | 1086 R | 1" | 0.0005 mm , 0.001 mm , 0.002 mm , 0.005 mm , 0.01 mm | Factory standard | IP 42 | CR 2450N (3V Lithium) | 0.004 mm | 0.001 mm | 0.65 - 1.15 | 11 mm | ||||||||||||||||||||||||||||||||||||||||||||||||||
Digital dial indicator 1086 Ri |
4337625 | 25 mm | 1086 Ri | 1" | 0.0005 mm , 0.001 mm , 0.002 mm , 0.005 mm , 0.01 mm | Factory standard | IP 42 | CR 2450N (3V Lithium) | 0.004 mm | 0.001 mm | 0.65 - 1.15 | 11 mm | ||||||||||||||||||||||||||||||||||||||||||||||||||
Compact amplifier C 1200 M |
5312012 | C 1200 M | IP 42 | 5 x LR6 (1,5V Mignon AA) possible | ± .19" , ± .07" , ± .03'' , ± .01'' , ± .003'' , ± .001'' , ± .0003" , ± .0001'' | TFT color display, 110 mm (4.3"), 480 x 272 pixels | ± 5000 | ± .19" | ± 5000 , ± 2000 , ± 1000 , ± 300 , ± 100 , ± 30 , ± 10 , ± 3 | 0,1 | 500 , 200 , 100 , 20 , 10 , 2 , 1 , 0,2 | .019" , .007" , .002" , .001" , .0002'' , .0001'' , .00002'' , .00001'' | 1 | Mahr | +A, -A | 1 | 1 | Max, Min, Max-Min | Keyboard | 40 fps | 30 Hz | 0.3% (min. 0.2 µm) | 0.25% of the end scale value / 0.3% of the displayed value | Opto RS-232C , USB , Digimatic , wireless | Opto RS-232C , USB , Digimatic , wireless | Power source , 230 V/115 V; 50/60 Hz , battery operation | 10 °C | 40 °C | 0 °C | 40 °C | 0.496 kg | |||||||||||||||||||||||||||||||
Inductive probe P2004 M |
5323010 | P2004 M | IP 64 | 0,75 N +/- 0,15 N | Mahr VLDT | 10 °C | 40 °C | 10 °C | 40 °C | -2 mm | 2 mm | -2.2 mm | 0 mm | 2.2 mm | 4.4 mm | Standard model | 0,2 N/mm | 0.3 % | 0.1 µm | 0.5 µm | 0.4 µm | 1.5 µm | 3 µm | 2.5 m | 20 °C | -10 °C | 80 °C | 0.15 µm/°C |
Products |
Variants and options