Millimar | Module for inductive probes

Millimar N 1704 U

Art. no. 5331142

Module for inductive probes Millimar N 1704 U

  • Flexibly configurable RS485 bus modules
  • Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
  • Synchronous data retrieval from multiple connected measuring probes
  • Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
  • Connects all compatible probe types using one module
  • Flexible and modular product combinations to tackle customer-specific measuring tasks
  • Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)

instruction manual

Millimar N 1704 U
  • Flexibly configurable RS485 bus modules
  • Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
  • Synchronous data retrieval from multiple connected measuring probes
  • Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
  • Connects all compatible measuring probe types using one module
  • Flexible and modular product combinations to tackle customer-specific measuring tasks
  • Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)
Millimar N 1704 U | Art. no. 5331142
Product type N 1704 U
Resolution µm 0,1
Measuring range, inductive probe ± 5000 , ± 2000 , ± 1000 , ± 500
Probe inputs
Compatibility Marposs
Configuration Millimar Cockpit Software
Data transmission rate 4189 Hz
Error limit 0,3 % (min. 0,2 μm)
Data interface RS-485
Energy supply + 5V from N 1700 Bus
Current consumption 180 mA
IP protection category IP 42
Working temperature MIN 10 °C
Working temperature MAX 35 °C
Operating temperature Min 0 °C
Operating temperature Max 40 °C
Temperature coefficient 0.02 µm/°C
Product weight 0.394 kg

Variety of applications for our products

Smart and flexible combination of measuring modules and software for solving customer-specific measuring tasks.
Label Art. no. Measuring range from Measuring range up to Product type Distance of lower stop MIN Distance of lower stop MAX Distance of upper stop MIN Distance of upper stop MAX Lifter / retraction Measuring force (N) Increase in measuring force Sensitivity deviation Repeatability fw (µm) Measuring value hysteresis fu (µm) Linearity deviation within +/- 0,5 mm Linearity deviation within +/- 1,0 mm Linearity deviation within +/- 2,0 mm IP protection category Cable length Working temperature Working temperature MIN Working temperature MAX Operating temperature Min Operating temperature Max Storage temperature MIN Storage temperature MAX Temperature coefficient Compatibility Linearity deviation within +/- 5,0 mm
5323013 Inductive probe
P2004 U
5323013 -2 mm 2 mm P2004 U -2.2 mm 0 mm 2.2 mm 4.4 mm Standard model 0,75 N +/- 0,15 N 0,2 N/mm 0.3 % 0.1 µm 0.5 µm 0.4 µm 1.5 µm 3 µm IP 64 2.5 m 20 °C 10 °C 40 °C 10 °C 40 °C -10 °C 80 °C 0.15 µm/°C Marposs
5323023 Inductive probe
P2004 UA
5323023 -2 mm 2 mm P2004 UA -2.2 mm 0 mm 2.2 mm 4.4 mm Vacuum lifter 0,75 N +/- 0,15 N 0,2 N/mm 0.3 % 0.1 µm 0.5 µm 0.4 µm 1.5 µm 3 µm IP 64 2.5 m 20 °C 10 °C 40 °C 10 °C 40 °C -10 °C 80 °C 0.15 µm/°C Marposs
5323033 Inductive probe
P2004 UB
5323033 -2 mm 2 mm P2004 UB -2.2 mm 0 mm 2.2 mm 4.4 mm Compressed air retraction (max. 1 bar) Depending upon air pressure 0.3 % 0.1 µm 0.5 µm 0.4 µm 1.5 µm 3 µm IP 64 2.5 m 20 °C 10 °C 40 °C 10 °C 40 °C -10 °C 80 °C 0.15 µm/°C Marposs
5324023 Inductive probe
P2010 UA
5324023 -5 mm 5 mm P2010 UA -5.3 mm 5.3 mm Vacuum lifter 0,75 N +/- 0,15 N 0,1 N/mm 0.3 % 0.2 µm 1 µm 4 µm IP 64 2.5 m 20 °C 10 °C 40 °C 10 °C 40 °C -10 °C 80 °C 0.15 µm/°C Marposs 20 µm
5324033 Inductive probe
P2010 UB
5324033 -5 mm 5 mm P2010 UB -5.3 mm 5.3 mm Compressed air retraction (max. 1 bar) Depending upon air pressure 0.3 % 0.2 µm 1 µm 4 µm IP 64 2.5 m 20 °C 10 °C 40 °C 10 °C 40 °C -10 °C 80 °C 0.15 µm/°C Marposs 20 µm
5324073 Inductive probe
P2104 UA
5324073 -2 mm 2 mm P2104 UA -2.2 mm 0 mm 8.4 mm 10.4 mm Vacuum lifter 0,75 N +/- 0,15 N 0,1 N/mm 0.3 % 0.2 µm 1 µm 0.5 µm 2 µm 4 µm IP 64 2.5 m 20 °C 10 °C 40 °C 10 °C 40 °C -10 °C 80 °C 0.15 µm/°C Marposs
5324083 Inductive probe
P2104 UB
5324083 -2 mm 2 mm P2104 UB -2.2 mm 0 mm 8.4 mm 10.4 mm Compressed air retraction (max. 1 bar) Depending upon air pressure 0.3 % 0.2 µm 1 µm 0.5 µm 2 µm 4 µm IP 64 2.5 m 20 °C 10 °C 40 °C 10 °C 40 °C -10 °C 80 °C 0.15 µm/°C Marposs
To top