Millimar |
Measuring software
Millimar Cockpit 13
Art. no. 5312865
MarWin 13 Millimar Cockpit software • Smart, universal software for complex measuring tasks in the manufacturing sector • Interactive, touch-sensitive software • Very simple and intuitive to use • The Millimar N 1700 modules support inductive probes as well as Mahr measuring instruments with USB or wireless interface • Password-protected user levels • Integrated Online Help can be accessed directly from the software • Data export to MS Excel or in qs-stat data format • System requirements: MS Windows 7 or 10, min. 2 free USB 2.0 interfaces
- Interactive, touch-sensitive software
- Very simple and intuitive to use
- User-friendly creation of measuring tasks
- Access to predefined wizards for maximum ease of use
- Management of measuring tasks (save and load function)
- Measuring task linked to images or drawings
- Static and dynamic recording of measuring values
- Supported by graphical operating elements
- Live visualization of measuring values
- Simultaneous display of 128 digital or analog measurement values
- The Millimar N 1700 modules support a wide range of inductive measuring probes as well as Mahr instruments with a data interface
- Connection of Mahr measuring technologies via Integrated Wireless
- Data export to MS Excel or in qs-Stat format (dfq or dfx/dfd format)
- Script export for capturing additional data and outputting measurement protocols
- Password-protected user levels (3 levels)
- Online help (operating instructions) can be accessed directly from the software
Millimar Cockpit 13 | Art. no. 5312865 | |
---|---|
Product type | Cockpit 13 |
Range of analog display µm | ± 10000 , ± 5000 , ± 2000 , ± 1000 , ± 500 , ± 200 , ± 100 , ± 50 , ± 20 , ± 10 , tolerance related |
Resolution µm | 0,01 |
Display |
Vertical bar display Horizontal bar display Analog display or round scale Digital display Display types per feature freely combinable |
Tolerance display |
Upper and lower tolerance limit (per characteristic) Upper and lower warning limit (per characteristic) |
Compatibility | USB , Integrated wireless , Millimar N 1700 |
Measuring combination |
Predefined formula templates for standard characteristics Input of links via extensive formula editor |
Features | 128 |
Classification | max. 20 classes |
Control inputs | via N 1704 I/O module (5331134) |
Control outputs | via N 1704 I/O module (5331134) |
Range of analog display inches | ± .5" , ± .2" , ± .1'' , ± .05" , ± .02" , ± .01'' , ± .005" , ± .002" , ± .001'' , ± .0005" , tolerance related |
Variety of applications for our products
Smart and universally applicable software for complex measurement tasks in the manufacturing sector
Label | Art. no. | Product type | Current supply | Configuration | Data interface | Operating temperature from | Operating temperature up to | Current consumption | Resolution µm | Measuring range, inductive probe | Probe inputs | Compatibility | Data transmission rate | Error limit | Energy supply | IP protection category | Working temperature MIN | Working temperature MAX | Temperature coefficient | Product weight | Zero setter | Control inputs | Control outputs | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
USB connecting module N 1701 USB |
5331130 | N 1701 USB | 430 mA | Millimar Cockpit Software | USB , RS-485 | 0 °C | 40 °C | |||||||||||||||||
Module for inductive probes N 1702 M |
5331120 | N 1702 M | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 115 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Mahr , Mahr 1340 , Mahr half-bridge , Mahr LVDT , Mahr VLDT | 4189 Hz | 0,3 % (min. 0,2 μm) | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Module for inductive probes N 1702 M-HR |
5331125 | N 1702 M-HR | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 115 mA | 0,01 | ± 200 | 2 | Mahr , Mahr 1340 , Mahr half-bridge , Mahr LVDT , Mahr VLDT | 4189 Hz | 0,3 % (min. 0,04 μm) | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Module for inductive probes N 1704 M |
5331140 | N 1704 M | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 180 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 4 | Mahr , Mahr half-bridge , Mahr LVDT , Mahr VLDT | 4189 Hz | 0,3 % (min. 0,2 μm) | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.394 kg | |||||
Module for inductive probes N 1702 T |
5331121 | N 1702 T | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 95 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Tesa | 4189 Hz | 0,3 % (min. 0,2 μm) | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Module for inductive probes N 1704 T |
5331141 | N 1704 T | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 150 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 4 | Tesa | 4189 Hz | 0,3 % (min. 0,2 μm) | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.394 kg | |||||
Module for inductive probes N 1702 U |
5331122 | N 1702 U | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 115 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Marposs | 4189 Hz | 0,3 % (min. 0,2 μm) | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Module for inductive probes N 1704 U |
5331142 | N 1704 U | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 180 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 4 | Marposs | 4189 Hz | 0,3 % (min. 0,2 μm) | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.394 kg | |||||
Module for pneumatic gages N 1701 PF-2500/5000 |
5331155 | N 1701 PF-2500/5000 | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 32 mA | 0,1 | Mahr-Federal | 4189 Hz | ± 0.8 µm in the range ± 38 µm and ± 0.5 µm in the range ± 25 µm | + 5V from N 1700 Bus | Electrical | |||||||||||
Power supply module N 1701 PS |
5331133 | N 1701 PS | 2000 mA | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 230 V/115 V; 50/60 Hz | ||||||||||||||||
I/O module N 1704 I/O |
5331134 | N 1704 I/O | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 70 mA | 4 inputs, 10 - 30 V |
4 outputs, 10 - 30 V ESD protected, short-circuit proof |
|||||||||||||||
Wireless receiver for measuring instruments with integrated wireless i-Stick |
4102220 | |||||||||||||||||||||||
Data connection cable USB 16 EXu |
4102357 | |||||||||||||||||||||||
Data connection cable USB 2000 USB |
4346023 | |||||||||||||||||||||||
Adapter cable RS-232-USB Millimar - USB |
4102331 |