Millimar |
Compact amplifier
Millimar C 1202
Art. no. 5312025
Compact amplifier Millimar C 1202
Features: 3
Connect different sensors by way of N1700 measuring modules
Range of analog display mm: ± 5, ± 2, ± 1, ± 0,3, ± 0,1, ± 0,03, ± 0,01, ± 0,003
Range of digital display mm: ± 999,9999
Data interface: USB, Digimatic
Energy supply: Power source, 230 V/115 V; 50/60 Hz
Package contains: power source, micro SD memory card, instruction manual, without N 1700 module (necessary optional accessory)
- Versatility for a wide range of measuring tasks
- Interchangeable N 1700 modules as measuring channels for inductive and
incremental probes or for pneumatic measuring equipment. - Perfect display thanks to high resolution and high contrast color screen
- Fully adjustable display for ideal viewing angle
- Variable display of measuring values, either as a number, pointer or bars
- 1 - 3 features can be displayed at once
- Extremely easy to operate
- Programmable switching input to control the measuring routine
- Flexible, multiple measuring tasks can be stored on the memory card.
- Compact housing
- Suitable for wall mounting
Millimar C 1202 | Art. no. 5312025 | |
---|---|
Product type | C 1202 |
Range of digital display µm | ± 999 999.9 |
Range of analog display µm | ± 5000 , ± 2000 , ± 1000 , ± 300 , ± 100 , ± 30 , ± 10 , ± 3 |
Resolution µm | 0,01 , 0,1 , 1 |
Graduation mm | 500 , 200 , 100 , 20 , 10 , 2 , 1 , 0,2 |
Graduation value inches | .019" , .007" , .002" , .001" , .0002'' , .0001'' , .00002'' , .00001'' |
Display | TFT color display, 110 mm (4.3"), 480 x 272 pixels |
Refresh rate | 30 fps |
Measuring combination | +A, -A, +B, -B, A+B, +A-B, -A+B, -A-B |
Features | 3 |
Test steps | 1 |
Dynamic functions | Max, Min, TIR (Max-Min), (Max+Min)/2, Average |
Statistical functions | Length, Angle |
Configuration | Keyboard |
Data transmission rate | 30 Hz |
Error limit, digital display |
0.3% (min. 0.2 μm); 0.3% (min. 0.04 μm)* * (with N 1702 M-HR) |
Error limit, analog display | 0.25% of the end scale value / 0.3% of the displayed value |
Data interface | USB , Digimatic |
Hardware interfaces | USB , Control input , RS-485 , Micro SD slot for SD / SDHC cards up to 32 GB |
Control inputs |
Control input programmable
(functions and function sequences) |
Energy supply | Power source , 230 V/115 V; 50/60 Hz |
IP protection category | IP 42 |
Working temperature MIN | 10 °C |
Working temperature MAX | 35 °C |
Operating temperature from | 0 °C |
Operating temperature up to | 40 °C |
Range of digital display inch | ± 39" |
Range of analog display inches | ± .19" , ± .07" , ± .03'' , ± .01'' , ± .003'' , ± .001'' , ± .0004" , ± .0001'' |
Variety of applications for our products
Indicating instrument for precise length measurements
- for connecting different sensors by way of N 1700 measuring modules
- for connecting up to 2 measuring sensors
Please note:
N 1700 measuring modules are necessary additional accessories
Label | Art. no. | Product type | Current consumption | Resolution µm | Measuring range, inductive probe | Probe inputs | Compatibility | Configuration | Data transmission rate | Error limit | Data interface | Energy supply | IP protection category | Working temperature MIN | Working temperature MAX | Operating temperature from | Operating temperature up to | Temperature coefficient | Product weight | Zero setter | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Module for inductive probes N 1702 M |
5331120 | N 1702 M | 115 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Mahr , Mahr 1340 , Mahr half-bridge , Mahr LVDT , Mahr VLDT | Millimar Cockpit Software | 4189 Hz | 0,3 % (min. 0,2 μm) | RS-485 | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0 °C | 40 °C | 0.02 µm/°C | 0.27 kg | ||
Module for inductive probes N 1702 M-HR |
5331125 | N 1702 M-HR | 115 mA | 0,01 | ± 200 | 2 | Mahr , Mahr 1340 , Mahr half-bridge , Mahr LVDT , Mahr VLDT | Millimar Cockpit Software | 4189 Hz | 0,3 % (min. 0,04 μm) | RS-485 | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0 °C | 40 °C | 0.02 µm/°C | 0.27 kg | ||
Module for inductive probes N 1702 T |
5331121 | N 1702 T | 95 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Tesa | Millimar Cockpit Software | 4189 Hz | 0,3 % (min. 0,2 μm) | RS-485 | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0 °C | 40 °C | 0.02 µm/°C | 0.27 kg | ||
Module for inductive probes N 1702 U |
5331122 | N 1702 U | 115 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Marposs | Millimar Cockpit Software | 4189 Hz | 0,3 % (min. 0,2 μm) | RS-485 | + 5V from N 1700 Bus | IP 42 | 10 °C | 35 °C | 0 °C | 40 °C | 0.02 µm/°C | 0.27 kg | ||
Module for incremental sensors N 1702 VPP |
5331161 | N 1702 VPP | 350 mA | 0,01 , 0,1 | 2 | Incremental 1 Vss | Millimar C 1202 as of FW version 1.1.0.0 | 4189 Hz | RS-485 | + 5V from N 1700 Bus | IP 42 | 10 °C | 30 °C | 0 °C | 40 °C | 0.2 kg | |||||
Module for pneumatic gages N 1701 PF-2500/5000 |
5331155 | N 1701 PF-2500/5000 | 32 mA | 0,1 | Mahr-Federal | Millimar Cockpit Software | 4189 Hz | ± 0.8 µm in the range ± 38 µm and ± 0.5 µm in the range ± 25 µm | RS-485 | + 5V from N 1700 Bus | 0 °C | 40 °C | Electrical | ||||||||
Module for pneumatic gages N 1701 PF-10000 |
5331157 | N 1701 PF-10000 | 32 mA | 0,1 | Mahr-Federal | Millimar Cockpit Software | 4189 Hz | ± 0.8 µm in the range ± 38 µm and ± 0.5 µm in the range ± 25 µm | RS-485 | + 5V from N 1700 Bus | 0 °C | 40 °C | Electrical | ||||||||
Extension rail for Millimar C 1202 to fit two N 1701 PF/PM modules |
5312950 | ||||||||||||||||||||
Data cable USB bidirectional DK-U1 |
4102603 | ||||||||||||||||||||
Data cable Digimatic DK-D1 |
4102606 | ||||||||||||||||||||
Foot switch to trigger data transmission 16 ESf |
4102058 |
Datasheet
Download
Millimar--C1202--3722995--BA--DE--2024-03-04--1-1-0-0--HQ.pdf
Download
Millimar--C1202--3723010--BA--EN--WEB--HQ--CC2020.pdf
Download
Millimar--C1202--3722972--BA--EN--2023-02-06--HQPR.pdf
Download
Millimar--C1202--3722972--BA--FR--2023-01-13--HQPR.pdf
Download
Millimar--C1202--3722972--BA--IT--2023-01-13--HQPR.pdf
Download
Millimar--C1202--3722997--BA--PL--2023-01-13--HQ.pdf
Download
Millimar--C1202--3723013--BA--ZH--WEB--HQ--CC2020.pdf
Download
Millimar--C1202--3722972--BA--ZH--2023-01-13--HQPR.pdf
Download
3765749_18.10.2021_A_D00007514_A.pdf_757596_0.pdf
Download
Products |
Variants and options