Millimar |
Measuring software
Millimar Cockpit 13
Nr art. 5312865
MarWin 13 Millimar Cockpit software • Smart, universal software for complex measuring tasks in the manufacturing sector • Interactive, touch-sensitive software • Very simple and intuitive to use • The Millimar N 1700 modules support inductive probes as well as Mahr measuring instruments with USB or wireless interface • Password-protected user levels • Integrated Online Help can be accessed directly from the software • Data export to MS Excel or in qs-stat data format • System requirements: MS Windows 7 or 10, min. 2 free USB 2.0 interfaces
- Interactive, touch-sensitive software
- Very simple and intuitive to use
- User-friendly creation of measuring tasks
- Access to predefined wizards for maximum ease of use
- Management of measuring tasks (save and load function)
- Measuring task linked to images or drawings
- Static and dynamic recording of measuring values
- Supported by graphical operating elements
- Live visualization of measuring values
- Simultaneous display of 128 digital or analog measurement values
- The Millimar N 1700 modules support a wide range of inductive measuring probes as well as Mahr instruments with a data interface
- Connection of Mahr measuring technologies via Integrated Wireless
- Data export to MS Excel or in qs-Stat format (dfq or dfx/dfd format)
- Script export for capturing additional data and outputting measurement protocols
- Password-protected user levels (3 levels)
- Online help (operating instructions) can be accessed directly from the software
Millimar Cockpit 13 | Nr art. 5312865 | |
---|---|
Typ produktu | Cockpit 13 |
Zakres wskazań podziałki µm | ± 10000 , ± 5000 , ± 2000 , ± 1000 , ± 500 , ± 200 , ± 100 , ± 50 , ± 20 , ± 10 , w odniesieniu do tolerancji |
Rozdzielczość µm | 0,01 |
Wyświetlacz |
Vertical bar display Horizontal bar display Analog display or round scale Digital display Display types per feature freely combinable |
Wskaźnik tolerancji |
Upper and lower tolerance limit (per characteristic) Upper and lower warning limit (per characteristic) |
Zgodność | USB , Zintegrowana łączność bezprzewodowa , Millimar N 1700 |
Kombinacje pomiarów |
Predefined formula templates for standard characteristics Input of links via extensive formula editor |
Cechy | 128 |
Klasyfikacja | max. 20 classes |
Wejścia sterujące | via N 1704 I/O moduł (5331134) |
Wyjścia sterujące | via N 1704 I/O moduł (5331134) |
Zakres wyświetlania podziałki – cale | ± .5" , ± .2" , ± .1'' , ± .05" , ± .02" , ± .01'' , ± .005" , ± .002" , ± .001'' , ± .0005" , w odniesieniu do tolerancji |
Różnorodne obszary wykorzystania naszego produktu
Inteligentne i wszechstronne oprogramowanie do złożonych zadań pomiarowych w sektorze produkcyjnym
Etykieta | Nr art. | Typ produktu | Zasilanie elektryczne | Konfigurowanie | Złącze danych | Temperatura robocza od | Temperatura robocza do | Pobór prądu | Rozdzielczość µm | Zakres pomiarowy czujnika indukcyjnego | Wejścia czujników | Zgodność | Prędkość przesyłu danych | Błąd graniczny | Zasilanie | Stopień ochrony IP | Temperatura robocza MIN | Temperatura robocza MAKS | Współczynnik temperaturowy | Masa produktu | Korektor zera | Wejścia sterujące | Wyjścia sterujące | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Moduł przyłączeniowy USB N 1701 USB |
5331130 | N 1701 USB | 430 mA | Oprogramowanie Millimar Cockpit | USB , RS-485 | 0 °C | 40 °C | |||||||||||||||||
Moduł do indukcyjnych głowic pomiarowych N 1702 M |
5331120 | N 1702 M | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 115 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Mahr , Mahr 1340 , Półmostek Mahr , LVDT Mahr , VLDT Mahr | 4189 Hz | 0,3% (min. 0,2 μm) | + 5 V z magistrali N 1700 | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Moduł do indukcyjnych głowic pomiarowych N 1702 M-HR |
5331125 | N 1702 M-HR | Millimar Cockpit Software | RS-485 | 0 °C | 40 °C | 115 mA | 0,01 | ± 200 | 2 | Mahr , Mahr 1340 , Półmostek Mahr , LVDT Mahr , VLDT Mahr | 4189 Hz | 0,3% (min. 0,04 μm) | + 5 V z magistrali N 1700 | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Moduł do indukcyjnych głowic pomiarowych N 1704 M |
5331140 | N 1704 M | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 180 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 4 | Mahr , Półmostek Mahr , LVDT Mahr , VLDT Mahr | 4189 Hz | 0,3% (min. 0,2 μm) | + 5 V z magistrali N 1700 | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.394 kg | |||||
Moduł do indukcyjnych głowic pomiarowych N 1702 T |
5331121 | N 1702 T | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 95 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Tesa | 4189 Hz | 0,3% (min. 0,2 μm) | + 5 V z magistrali N 1700 | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Moduł do indukcyjnych głowic pomiarowych N 1704 T |
5331141 | N 1704 T | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 150 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 4 | Tesa | 4189 Hz | 0,3% (min. 0,2 μm) | + 5 V z magistrali N 1700 | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.394 kg | |||||
Moduł do indukcyjnych głowic pomiarowych N 1702 U |
5331122 | N 1702 U | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 115 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 2 | Marposs | 4189 Hz | 0,3% (min. 0,2 μm) | + 5 V z magistrali N 1700 | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.27 kg | |||||
Moduł do indukcyjnych głowic pomiarowych N 1704 U |
5331142 | N 1704 U | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 180 mA | 0,1 | ± 5000 , ± 2000 , ± 1000 , ± 500 | 4 | Marposs | 4189 Hz | 0,3% (min. 0,2 μm) | + 5 V z magistrali N 1700 | IP 42 | 10 °C | 35 °C | 0.02 µm/°C | 0.394 kg | |||||
moduł do pneumatycznego sprzętu pomiarowego N 1701 PF-2500/5000 |
5331155 | N 1701 PF-2500/5000 | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 32 mA | 0,1 | Mahr-Federal | 4189 Hz | ± 0,8 µm w zakresie ± 38 µm i ± 0,5 µm w zakresie ± 25 µm | + 5 V z magistrali N 1700 | Elektryczny | |||||||||||
Moduł zasilania elektrycznego N 1701 PS |
5331133 | N 1701 PS | 2000 mA | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 230 V/115 V; 50/60 Hz | ||||||||||||||||
Moduł wejściowy / wyjściowy N 1704 I/O |
5331134 | N 1704 I/O | Oprogramowanie Millimar Cockpit | RS-485 | 0 °C | 40 °C | 70 mA | 4 wejścia, 10-30 V |
4 wyjścia, 10 - 30 V z ochroną przed ESD, odporne na zwarcia |
|||||||||||||||
Odbiornik radiowy do przyrządów pomiarowych z łącznością Integrated Wireless i-Stick |
4102220 | |||||||||||||||||||||||
Kabel do transmisji danych USB 16 EXu |
4102357 | |||||||||||||||||||||||
Kabel do transmisji danych USB 2000 USB |
4346023 | |||||||||||||||||||||||
Kabel przejściowy RS-232-USB Millimar - USB |
4102331 |