Millimar |
Module for inductive probes
Millimar N 1702 U
Art. no. 5331122
Module for inductive probes Millimar N 1702 U
- Flexibly configurable RS485 bus modules
- Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
- Synchronous data retrieval from multiple connected measuring probes
- Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
- Connects all compatible probe types using one module
- Flexible and modular product combinations to tackle customer-specific measuring tasks
- Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)
instruction manual
- Flexibly configurable RS485 bus modules
- Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
- Synchronous data retrieval from multiple connected measuring probes
- Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
- Connects all compatible measuring probe types using one module
- Flexible and modular product combinations to tackle customer-specific measuring tasks
- Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)
Millimar N 1702 U | Art. no. 5331122 | |
---|---|
Product type | N 1702 U |
Current consumption | 115 mA |
Resolution µm | 0,1 |
Measuring range, inductive probe | ± 5000 , ± 2000 , ± 1000 , ± 500 |
Probe inputs | 2 |
Compatibility | Marposs |
Configuration | Millimar Cockpit Software |
Data transmission rate | 4189 Hz |
Error limit | 0,3 % (min. 0,2 μm) |
Data interface | RS-485 |
Energy supply | + 5V from N 1700 Bus |
IP protection category | IP 42 |
Working temperature MIN | 10 °C |
Working temperature MAX | 35 °C |
Operating temperature from | 0 °C |
Operating temperature up to | 40 °C |
Temperature coefficient | 0.02 µm/°C |
Product weight | 0.27 kg |
Variety of applications for our products
Smart and flexible combination of measuring modules and software for solving customer-specific measuring tasks.
Label | Art. no. | Product type | |
---|---|---|---|
![]() |
Inductive probe P2004 U |
5323013 | P2004 U |
![]() |
Inductive probe P2004 UA |
5323023 | P2004 UA |
![]() |
Inductive probe P2004 UB |
5323033 | P2004 UB |
![]() |
Inductive probe P2010 UA |
5324023 | P2010 UA |
![]() |
Inductive probe P2010 UB |
5324033 | P2010 UB |
![]() |
Inductive probe P2104 UA |
5324073 | P2104 UA |
![]() |
Inductive probe P2104 UB |
5324083 | P2104 UB |
Datasheet
Download
Products |
Variants and options
Millimar |
Module for inductive probes
Millimar N 1702 U
Art. no. 5331122
Module for inductive probes Millimar N 1702 U
- Flexibly configurable RS485 bus modules
- Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
- Synchronous data retrieval from multiple connected measuring probes
- Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
- Connects all compatible probe types using one module
- Flexible and modular product combinations to tackle customer-specific measuring tasks
- Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)
instruction manual
- Flexibly configurable RS485 bus modules
- Powerful connection modules for evaluating measuring sensors (inductive/pneumatic)
- Synchronous data retrieval from multiple connected measuring probes
- Connection of N 1700 modules via USB interface to the smart, universal evaluation and configuration software Millimar Cockpit
- Connects all compatible measuring probe types using one module
- Flexible and modular product combinations to tackle customer-specific measuring tasks
- Maximum theoretical bus data rate of 4189 values/s (depending on the number of connected channels)
Millimar N 1702 U | Art. no. 5331122 | |
---|---|
Product type | N 1702 U |
Current consumption | 115 mA |
Resolution µm | 0,1 |
Measuring range, inductive probe | ± 5000 , ± 2000 , ± 1000 , ± 500 |
Probe inputs | 2 |
Compatibility | Marposs |
Configuration | Millimar Cockpit Software |
Data transmission rate | 4189 Hz |
Error limit | 0,3 % (min. 0,2 μm) |
Data interface | RS-485 |
Energy supply | + 5V from N 1700 Bus |
IP protection category | IP 42 |
Working temperature MIN | 10 °C |
Working temperature MAX | 35 °C |
Operating temperature from | 0 °C |
Operating temperature up to | 40 °C |
Temperature coefficient | 0.02 µm/°C |
Product weight | 0.27 kg |
Variety of applications for our products
Smart and flexible combination of measuring modules and software for solving customer-specific measuring tasks.
Label | Art. no. | Product type | |
---|---|---|---|
![]() |
Inductive probe P2004 U |
5323013 | P2004 U |
![]() |
Inductive probe P2004 UA |
5323023 | P2004 UA |
![]() |
Inductive probe P2004 UB |
5323033 | P2004 UB |
![]() |
Inductive probe P2010 UA |
5324023 | P2010 UA |
![]() |
Inductive probe P2010 UB |
5324033 | P2010 UB |
![]() |
Inductive probe P2104 UA |
5324073 | P2104 UA |
![]() |
Inductive probe P2104 UB |
5324083 | P2104 UB |
Datasheet
Download
Products |
Variants and options